摘要

The purpose of this paper is to model an Enhanced Geothermal System (EGS) power plant using an Organic Rankine Cycle (ORC) cooled by a Natural Draft Dry Cooling Tower (NDDCT) and to investigate the influence of the variation of performance of the NDDCT due to changing ambient temperature on cycle performance. The ORC used in this work is the supercritical butene recuperated ORC. The EGS heat source conditions used are those found at the Habanero 1 MW pilot plant in South Australia, with geothermal brine inlet temperature of 220 degrees C, minimum brine temperature of 80 degrees C, and brine mass flow rate of 35 kg/s. A one dimensional NDDCT model was developed and integrated into the cycle model, enabling a novel method of coupled analysis of ORC and NDDCT interdependence, which allows analysis of plant performance for varying ambient temperature. The analysis finds that annual average (W) over dot(net) is 2.82 MWe, the typical daily range of (W) over dot(net) is 0.62 MWe (+/- 11%), the typical change in (W) over dot(net,mean) for consecutive days is 0.07 MWe (3%), and the largest is 0.5 MWe (20%). The maximum range at any given time throughout the year, based on historical temperature data extremes is +/- 31%, but the typical expected range +/- 10%.

  • 出版日期2016-7-25