Fast fMRI provides high statistical power in the analysis of epileptic networks

作者:Jacobs Julia*; Stich Julia; Zahneisen Benjamin; Asslaender Jakob; Ramantani Georgia; Schulze Bonhage Andreas; Korinthenberg Rudolph; Hennig Juegen; LeVan Pierre
来源:NeuroImage, 2014, 88: 282-294.
DOI:10.1016/j.neuroimage.2013.10.018

摘要

EEG-fMRI is a unique method to combine the high temporal resolution of EEG with the high spatial resolution of MRI to study generators of intrinsic brain signals such as sleep grapho-elements or epileptic spikes. While the standard EPI sequence in fMRI experiments has a temporal resolution of around 2.5-3 s a newly established fast fMRI sequence called MREG (Magnetic-Resonance-Encephalography) provides a temporal resolution of around 100 ms. This technical novelty promises to improve statistics, facilitate correction of physiological artifacts and improve the understanding of epileptic networks in fMRI. The present study compares simultaneous EEG-EP1 and EEG-MREG analyzing epileptic spikes to determine the yield of fast MRI in the analysis of intrinsic brain signals. Patients with frequent interictal spikes (>3120 min) underwent EEG-MREG and EEG-EPI (3 T, 20 min each, voxel size 3 x 3 x 3 mm, EPI TR= 2.61s, MREG TR = 0.1 s). Timings of the spikes were used in an event-related analysis to generate activation maps oft-statistics. (FMRISTAT, vertical bar t vertical bar > 3.5, cluster size: 7 voxels, p < 0.05 corrected). For both sequences, the amplitude and location of significant BOLD activations were compared with the spike topography. 13 patients were recorded and 33 different spike types could be analyzed. Peak T-values were significantly higher in MREG than in EPI (p<0.0001). Positive BOLD effects correlating with the spike topography were found in 8/29 spike types using the EP1 and in 22/33 spikes types using the MREG sequence. Negative BOLD responses in the default mode network could be observed in 3/29 spike types with the EPI and in 19/33 with the MREG sequence. With the latter method, BOLD changes were observed even when few spikes occurred during the investigation. Simultaneous EEG-MREG thus is possible with good EEG quality and shows higher sensitivity in regard to the localization of spike-related BOLD responses than EEG-EPI. The development of new methods of analysis for this sequence such as modeling of physiological noise, temporal analysis of the BOLD signal and defining appropriate thresholds is required to fully profit from its high temporal resolution.

  • 出版日期2014-3