摘要

Ductility-dip cracking (DDC) in the base metal heat-affected zone (HAZ) of NiCr15Fe-type alloys was studied using the programmable-deformation-crack (PVR) and the strain-to-fracture (STF) test. This paper concentrates on the correlation of the different cracking criteria used in both tests for DDC susceptibility assessment. Full temperature-strain curves were developed for three base metal NiCr15Fe-alloy variants using the STF test. The results were compared to a previous material ranking obtained by PVR testing. To determine a local cracking criterion for base metal DDC in the PVR test, a finite element analysis (FEM) was conducted on the thermomechanical aspects of crack initiation during PVR testing. The local temperature and strain conditions associated with DDC in the PVR base metal HAZ were observed and discussed with regard to the comparability and transferability of the cracking criteria used in the PVR and STF test.

  • 出版日期2016-9