摘要

The development of in situ vapour sampling methods to measure H-2 and O-18 in pore water of deep, unsaturated soil profiles, including mine tailings and waste rock, is required to improve our ability to track water migration through these deposits. To develop appropriate field sampling methods, a laboratory study was first undertaken to evaluate potential materials and sampling methods to collect and analyse vapour samples from unsaturated mine waste. Field methods were developed based on these findings and tested at two mine sites using either on-site analyses with a portable isotope laser spectrometer or sample collection and storage prior to laboratory analyses. The field sites included a series of deep (>50 m) multiport profiles within a coal waste rock dump and open wells installed in a sand tailings dyke at an oil sands mine. Laboratory results show that memory effects in sample bags and tubing require 3-5 pore volumes of vapour flushing prior to sample collection and sample storage times are limited to 24 h. Field sampling highlighted a number of challenges including the need to correct for sample humidity and in situ temperature. Best results were obtained when a portable laser spectrometer was used to measure vapour samples in situ.

  • 出版日期2016-10
  • 单位Saskatoon; Saskatchewan