摘要

Here, a conduction micropump with symmetric planar electrode pairs prepared on flame-retardant glass-reinforced epoxy (FR-4) copper-clad laminate (CCL) is fabricated. It is used to investigate the influence of chamber dimensions on the performance of a conduction micropump and to determine the reliability of the conduction pump when acetone is used as the working fluid. A testing platform is set up to evaluate conduction micropump performance under different conditions. When the chamber height is 0.2 mm, the pump pressure reaches its peak value.