摘要

in this paper, a new fouling measurement method is presented as a pragmatic approach to determine a mixed liquor's fouling propensity The MBR-VFM (VITO Fouling Measurement) uses a specific measurement protocol consisting of alternating filtration and physical cleaning steps, which enables the calculation of both the reversible and the irreversible fouling resistances. The MBR-VFM principle, set-up and measurement protocol are described as well as the evaluation of the fouling measurement method. Finally, the MBR-VFM was validated by comparing the fouling propensity measured on-line by the MBR-VFM in a lab-scale MBR with the fouling of the MBR membranes themselves. Our experiments indicated that the MBR-VFM can accurately measure fouling and that it can even be detected earlier than can be seen from the on-line filtration data of the lab-scale system itself Furthermore, the differences measured in reversible and irreversible fouling seemed to be related to the observed impact of physical and chemical cleaning respectively. Therefore, the application of the MBR-VFM as an on-line sensor in an advanced control system, enabling the deployment of the measured fouling data for the control of membrane cleaning, seems feasible and will be tested in the near future.

  • 出版日期2008-10-1