Assessment of skin dose modification caused by application of immobilizing cast in head and neck radiotherapy

作者:Soleymanifard Shokouhozaman; Toossi Mohammad Taghi Bahreyni*; Khosroabadi Mohsen; Noghreiyan Atefeh Vejdani; Shahidsales Soodabeh; Tabrizi Fatemeh Varshoee
来源:Australasian Physical & Engineering Sciences in Medicine, 2014, 37(3): 535-540.
DOI:10.1007/s13246-014-0283-8

摘要

Skin dose assessment for radiotherapy patients is important to ensure that the dose received by skin is not excessive and does not cause skin reactions. Immobilizing casts may have a buildup effect, and can enhance the skin dose. This study has quantified changes to the surface dose as a result of head and neck immobilizing casts. Medtech and Renfu casts were stretched on the head of an Alderson Rando-Phantom. Irradiation was performed using 6 and 15 MV X-rays, and surface dose was measured by thermoluminescence dosimeters. In the case of 15MV photons, immobilizing casts had no effect on the surface dose. However, the mean surface dose increase reached up to 20 % when 6MV X-rays were applied. Radiation incidence angle, thickness, and meshed pattern of the casts affected the quantity of dose enhancement. For vertical beams, the surface dose increase was more than tangential beams, and when doses of the points under different areas of the casts were analysed separately, results showed that only doses of the points under the thick area had been changed. Doses of the points under the thin area and those within the holes were identical to the same points without immobilizing casts. Higher dose which was incurred due to application of immobilizing casts (20 %) would not affect the quality of life and treatment of patients whose head and neck are treated. Therefore, the benefits of head and neck thermoplastic casts are more than their detriments. However, producing thinner casts with larger holes may reduce the dose enhancement effect.

  • 出版日期2014-9