摘要

A full understanding of the mechanisms of action in the percutaneous triple hemisection technique for tendo-achilles lengthening has yet to be acquired and therefore, an accurate prediction of the amount of lengthening that occurs is difficult to make. The purpose of this research was to develop a phenomenological damage model that utilizes both matrix and fiber damage and replicates the observed behavior of the tendon tissue during the lengthening process. Matrix damage was triggered and evolved relative to shear strain and the fiber damage was triggered and evolved relative to fiber stretch. Three examples are given to show the effectiveness of the model. Implementation of the damage model provides a tool for studying this common procedure, and may allow for numerical investigation of alternative surgical approaches that could reduce the incidence rates of severe over-lengthening.

  • 出版日期2014-10-17