摘要

Thermal performance of vertical U-pipe borehole heat exchanger (BHE) is an important research subject for the design and application of ground-coupled heat pump system (GCHPs). This paper presents an improved evaluation method for thermal performance of BHE based on analytical solution model, which is validated by comparing with duct storage system (DST) model and field experiment. Using the evaluation method, impacts of inlet fluid temperature, fluid flow rate and borehole depth on thermal performance of two types of U-pipe BHEs are studied. The study provides a good alternative of the experimental method for thermal performance test (TPT) and a useful thermal performance evaluation tool for BHEs in GCHPs.