摘要

Two analytical methodologies for the simultaneous analysis of eight sulfonamide antibiotics in animal feeds were developed. Analytes were extracted in a simple and rapid procedure by manual shaking with an ethyl acetate/ultrapure water mixture (99:1, v/v) without further sample cleanup. Mean recoveries ranging from 72.7% to 99.4% with relative standard deviations below 9% were achieved from spiked animal feed samples. Determination was carried out by high-performance liquid chromatography using fluorometric detection with precolumn derivatization. The separation of the derivatized compounds was performed using two different chromatographic columns: a conventional C(18) column and a recently available core-shell particle Kinetex C(18) column. Both methods were validated in-house in six different feed matrices, and the two approaches were compared. The experiments showed that the method using the Kinetex column was superior with regard to speed of analysis and precision, both under repeatability and intermediate reproducibility conditions. The limits of detection and quantification were also greatly improved, below 0.10 and 0.34 mu/g respectively. Finally, this novel approach was successfully applied to the analysis of real feed samples.

  • 出版日期2011-5-25