摘要

A major limitation of the cross-section electron beam-induced current methodthe use of roughly fractured surfaces to provide the cross-sectionhas been overcome with the use of focused ion beam microscope sample preparation. Using this method, it was possible to undertake a study of the relation between junction position and the corresponding external quantum efficiency (EQE) curves. For the case of cadmium telluride (CdTe) cells, it was demonstrated that the EQE curve shape that indicates a buried CdTe homojunction only arises if the junction is buried by more than 0.9 mu m from the heterointerface. This highlights the limitations of interpreting EQE curve shape to determine junction position. It was also shown that extended postgrowth annealing degrades the cadmium sulfide by Kirkendall voiding, and this leads to efficiency loss.

  • 出版日期2014-10