A Novel Automated Platform for Quantifying the Extent of Skeletal Tumour Involvement in Prostate Cancer Patients Using the Bone Scan Index

作者:Ulmert David; Kaboteh Reza; Fox Josef J; Savage Caroline; Evans Michael J; Lilja Hans; Abrahamsson Per Anders; Bjork Thomas; Gerdtsson Axel; Bjartell Anders; Gjertsson Peter; Hoglund Peter; Lomsky Milan; Ohlsson Mattias; Richter Jens; Sadik May; Morris Michael J; Scher Howard I; Sjostrand Karl; Yu Alice; Suurkula Madis; Edenbrandt Lars; Larson Steven M*
来源:European Urology, 2012, 62(1): 78-84.
DOI:10.1016/j.eururo.2012.01.037

摘要

Background: There is little consensus on a standard approach to analysing bone scan images. The Bone Scan Index (BSI) is predictive of survival in patients with progressive prostate cancer (PCa), but the popularity of this metric is hampered by the tedium of the manual calculation. %26lt;br%26gt;Objective: Develop a fully automated method of quantifying the BSI and determining the clinical value of automated BSI measurements beyond conventional clinical and pathologic features. %26lt;br%26gt;Design, setting, and participants: We conditioned a computer-assisted diagnosis system identifying metastatic lesions on a bone scan to automatically compute BSI measurements. A training group of 795 bone scans was used in the conditioning process. Independent validation of the method used bone scans obtained %26lt;= 3 mo from diagnosis of 384 PCa cases in two large population-based cohorts. An experienced analyser (blinded to case identity, prior BSI, and outcome) scored the BSI measurements twice. We measured prediction of outcome using pretreatment Gleason score, clinical stage, and prostate-specific antigen with models that also incorporated either manual or automated BSI measurements. %26lt;br%26gt;Measurements: The agreement between methods was evaluated using Pearson%26apos;s correlation coefficient. Discrimination between prognostic models was assessed using the concordance index (C-index). %26lt;br%26gt;Results and limitations: Manual and automated BSI measurements were strongly correlated (rho = 0.80), correlated more closely (rho = 0.93) when excluding cases with BSI scores %26gt;= 10 (1.8%), and were independently associated with PCa death (p %26lt; 0.0001 for each) when added to the prediction model. Predictive accuracy of the base model (C-index: 0.768; 95% confidence interval [CI], 0.702-0.837) increased to 0.794 (95% CI, 0.727-0.860) by adding manual BSI scoring, and increased to 0.825 (95% CI, 0.754-0.881) by adding automated BSI scoring to the base model. %26lt;br%26gt;Conclusions: Automated BSI scoring, with its 100% reproducibility, reduces turnaround time, eliminates operator-dependent subjectivity, and provides important clinical information comparable to that of manual BSI scoring.

  • 出版日期2012-7