摘要

Non-thermal plasma jet was generated by applying a dc source voltage between the syringe needle anode with flowing Argon gas and a planar or a hollow copper cathode in an atmospheric-pressure environment. The two operating discharge modes, which were self-pulsing and a continuous discharge mode, these were mainly controlled by the limitations of the current flowing in the discharge circuit. A ballast resistor was an important factor in affecting the limitations of the operating discharge mode. The gas breakdown was initially generated in the self-pulsing discharge mode at the source voltage of 1.2 kV. This was slightly higher than the breakdown voltage at the experimental condition of 1 lpm of Argon and a 1mm electrode gap distance. The peak self-pulsing discharge currents were up to 15-20A with a self-pulsing frequency in the range of 10-20 kHz. The continuous discharge mode could be observed at the higher source voltage with the continuous discharge current within the range of a few milliamperes.

  • 出版日期2016-7