Use of Knotless Suture for Closure of Total Hip and Knee Arthroplasties A Prospective, Randomized Clinical Trial

作者:Ting Nicholas T; Moric Mario M; Della Valle Craig J; Levine Brett R*
来源:Journal of Arthroplasty, 2012, 27(10): 1783-1788.
DOI:10.1016/j.arth.2012.05.022

摘要

We performed a prospective, randomized clinical trial to evaluate the efficacy of using a bidirectional barbed suture compared with traditional sutures in the deep closure of primary total hip (25) and knee (35) arthroplasties. Complications, time to closure, and length of surgery were evaluated. Closure was noted to be significantly faster (9.3 vs 13.6 minutes, P%26lt;.005) in the barbed suture group. Wound-related complications were similar (3 cases) in both groups at 3-month follow-up. Although this study supports the use of barbed technology as a functionally comparable and more efficient modality of wound closure with the potential for costs savings based on reduced operative time, the cost-effectiveness of its adoption is institution dependent and will rely on the optimization of all other perioperative factors.

  • 出版日期2012-12