摘要

In this study, a new experimental method is proposed to measure the real area of contact between a ceramic sphere and an Al surface based on the adhesive transfer of the Au film and the scanning electron microscope (SEM) in the back-scattered mode. A thin film of Au is sputtered on the ceramic sphere before the indentation with the Al surface. The success of this method relies on the fundamental assumption that the adhesive transfer of Au only occurs everywhere inside the contact area. A thin polymer (PMMA) film is deposited between gold film and the ceramic surface to further reduce adhesive strength. After indentation, the interfaces of the ceramic sphere and Al surface are observed by SEM. Experimental evidence that the adhesive transfer of the Au film occurs inside the contact area is given. The entire contact regions on the ceramic sphere and the Al surface are captured in the second electron and back-scattered images with a magnification of 220x (resolution: 432 nm, i.e., distance between neighboring pixels). The contact area can be identified based on both the distributions of the ceramic and Au on the ceramic sphere and Al surface, respectively. The back-scattered images with the magnifications of 5000x and 10,000x (resolution: 20 and 4 nm) are captured at four different locations along the radial direction (starting from the contact center), respectively. The real area of contact decreases from the center to the contact edge.

  • 出版日期2018-3