New Markers for Ventricular Repolarization in Coronary Slow Flow: Tp-e Interval, Tp-e/QT Ratio, and Tp-e/QTc Ratio

作者:Karaman Kayihan*; Altunkas Fatih; Cetin Mustafa; Karayakali Metin; Arisoy Arif; Akar Ilker; Zencir Cemil; Ayguc Baris; Celik Atac
来源:Annals of Noninvasive Electrocardiology, 2015, 20(4): 338-344.
DOI:10.1111/anec.12203

摘要

BackgroundCoronary slow flow (CSF) is characterized by normal or near-normal coronary arteries with delayed opacification of the distal vasculature that it may cause angina pectoris, acute myocardial infarction, life-threatening arrhythmias, and sudden cardiac death. The Tp-e interval, Tp-e/QT ratio, and Tp-e/QTc ratio are also known as predictors of ventricular arrhythmogenesis. The aim of this study was to assess ventricular repolarization in patients with CSF by using Tp-e interval, Tp-e/QT ratio, and Tp-e/QTc ratio. MethodsThis study included 50 patients with CSF and 51 control subjects. Coronary flow rates of all subjects were documented by thrombolysis in myocardial infarction (TIMI) frame count (TFC). Tp-e interval, Tp-e/QT ratio, and Tp-e/QTc ratio were measured from the 12-lead electrocardiogram. These parameters were compared between groups. ResultsIn electrocardiographic parameters analysis, QT, QTc, QTd, and QTcd were significantly increased in CSF patients compared with the control subjects (P < 0.001, P = 0.019, P < 0.001, P < 0.001, respectively). The Tp-e interval, Tp-e/QT ratio, and Tp-e/QTc ratio in the CSF patients were significantly higher than those in the control subjects (Tp-e: 117 21 milliseconds [ms] vs 96 +/- 16 ms, P < 0.001; Tp-e/QT: 0.30 +/- 0.06 vs 0.27 +/- 0.06, P = 0.005; Tp-e/QTc: 0.27 +/- 0.06 vs 0.24 +/- 0.05, P < 0.001). In the multivariate analysis, increased Tp-e and Tp-e/QT ratio were associated with CSF. ConclusionsOur study revealed that when compared to the control subjects, Tp-e interval, Tp-e/QT ratio, and Tp-e/QTc were significantly increased in the CSF patients.

  • 出版日期2015-7