摘要

Reactive oxygen species (ROS), especially HOCl/ClO-, have been demonstrated to play essential roles in both physiological and pathological processes, and an abnormal level of HOCl/ClO- is related to some diseases. In this work, a very fast responsive (within 30 seconds) porphyrin-based fluorescent probe, TPP-TCF, for ClO- with a NIR emissive wavelength was prepared. This probe exhibited excellent selectivity towards ClO- and would not be interfered with by other ROS and typical nucleophiles. The limit of detection (LOD) for ClO- was evaluated to be 0.29 mu M, indicating high sensitivity towards ClO-. In further bioimaging experiments, TPP-TCF displayed low-cytotoxicity and good cell penetrability for recognizing exogenous ClO- in HeLa cells. Moreover, this probe was successfully applied in imaging endogenous ClO- in living animals.

  • 出版日期2018-6-7
  • 单位医药生物技术国家重点实验室; 生命分析化学国家重点实验室; 南京大学