Measuring droplet fall speed with a high-speed camera: indoor accuracy and potential outdoor applications

作者:Yu Cheng Ku*; Hsieh Pei Rong; Yuter Sandra E; Cheng Lin Wen; Tsai Chia Lun; Lin Che Yu; Chen Ying
来源:Atmospheric Measurement Techniques, 2016, 9(4): 1755-1766.
DOI:10.5194/amt-9-1755-2016

摘要

Acquisition of accurate raindrop fall speed measurements outdoors in natural rain by means of moderatecost and easy-to-use devices represents a long-standing and challenging issue in the meteorological community. Feasibility experiments were conducted to evaluate the indoor accuracy of fall speed measurements made with a high-speed camera and to evaluate its capability for outdoor applications. An indoor experiment operating in calm conditions showed that the high-speed imaging technique can provide fall speed measurements with a mean error of 4.1-9.7% compared to Gunn and Kinzer's empirical fall-speed-size relationship for typical sizes of rain and drizzle drops. Results obtained using the same apparatus outside in summer afternoon showers indicated larger positive and negative velocity deviations compared to the indoor measurements. These observed deviations suggest that ambient flow and turbulence play a role in modifying drop fall speeds which can be quantified with future outdoor high-speed camera measurements. Because the fall speed measurements, as presented in this article, are analyzed on the basis of tracking individual, specific raindrops, sampling uncertainties commonly found in the widely adopted optical disdrometers can be significantly mitigated.

  • 出版日期2016