A novel and sensitive method for ethinylestradiol quantification in human plasma by high-performance liquid chromatography coupled to atmospheric pressure photoionization (APPI) tandem mass spectrometry: Application to a comparative pharmacokinetics study

作者:Borges Ney Carter*; Astigarraga Rafael Barrientos; Sverdloff Carlos Eduardo; Galvinas Paulo Rabelo; da Silva Washington Moreira; Rezende Vinicius Marcondes; Moreno Ronilson Agnaldo
来源:Journal of Chromatography B-Analytical Technologies in the Biomedical and Life Sciences, 2009, 877(29): 3601-3609.
DOI:10.1016/j.jchromb.2009.08.048

摘要

In the present Study, a novel, fast, sensitive and robust method to quantify ethinylestradiol in human plasma using 17 alpha-ethinylestradiol-d4 as the internal standard (IS) is described. The analyte and the IS were extracted from acidified plasma by liquid-liquid extraction (LLE) using diethyl ether-hexane followed by online solid phase extraction (SPE) using online C18 cartridges. Extracted samples were analyzed by high-performance liquid chromatography coupled to atmospheric pressure photoionization tandem mass spectrometry (HPLC-APPI-MS/MS). Chromatography was performed isocratically on a C18, 5 mu m analytical column. The method had a chromatographic run time of 2.50 min and a linear calibration Curve over the range 5-500 pg ml(-1) (r(2) > 0.9992). The lowest concentration quantified was 5 pg ml(-1), demonstrating acceptable accuracy and precision. The intra-assay precisions ranged from 2.1 to 14.6%. while inter-assay precisions ranged from 4.4 to 11.4%. The intra-assay accuracies ranged from 94.6 to 103.8%, while the inter-assay accuracies ranged from 98.9 to 101.6%. The recovery of ethinylestradiol was determined as part of the assay validation process and was 73.1 and 79.0% for the concentrations 15 and 375 pg ml(-1). respectively. Short-term stability showed that ethinylestradiol was stable in plasma for at least 19 h at room temperature or for at least 385 days when stored at -20 degrees C. In the study of bioequivalence conducted in Brazil, healthy Volunteers received two ethinylestradiol 0.035 mg tablet formulations using an open, randomized, two-period crossover design with a 2-week washout interval. Since the 90% confidence interval for C(max) and area under the curve ratios were all inside the 80-125% interval proposed by the US Food and Drug Administration, it was concluded that the two ethinylestradiol formulations are bioequivalent with respect to both the rate and the extent of absorption.

  • 出版日期2009-11-1