摘要

Insulation is typically used in extra-large double-walled cryogenic storage tanks that are used to store liquid natural gas (LNG). These vessels have been designed with the assumption that the insulation offers negligible structural resistance that might cause structural damage. Observation of the deformation of the insulation in such tanks leads to concern that the insulation may become sufficiently compacted to cause significant load transfer between the inner and outer tank. The inner tank, though protected from most external events by the outer tank, is only designed to contain the liquid gas. It is therefore much more sensitive to seismic effects. In this investigation, simplified and 3D finite element models are used to simulate the interaction effects of the fluid, inner tank, insulation and outer tank. This paper presents an initial analysis of the potential effects of LNG tank insulation under earthquake conditions and assesses the potential for structural damage by comparison of models that do or do not consider the insulation layer. The data reported and statistically sorted include the overturning moment, the base shear, the tank wall stress, and the wave height in the tank. The results show that the insulation layer has certain influence on seismic design of LNG tanks.