摘要

An innovative design for Chinese pressurized reactor is the steam generator (SG) secondary side water cooling passive residual heat removal system (PRHRS). The new design is expected to improve reliability and safety of the Chinese pressurized reactor during the event of feed line break or station blackout (SBO) accident. The new system is comprised of a SG, a cooling water pool, a heat exchanger (HX), an emergency makeup tank (EMT) and corresponding valves and pipes. In order to evaluate the reliability of the water cooling PRHRS, an analysis tool was developed based on the drift flux mixture flow model. The preliminary validation of the analysis tool was made by comparing to the experimental data of ESPRIT facility. Calculation results under both high pressure condition and low pressure condition fitted the experimental data remarkably well. A hypothetical SBO accident was studied by taking the residual power table under SBO accident as the input condition of the analysis tool. The calculation results showed that the EMT could supply the water to the SG shell side successfully during SBO accident. The residual power could be taken away successfully by the two-phase natural circulation established in the water cooling PRHRS loop. Results indicate the analysis tool can be used to study the steady and transient operating characteristics of the water cooling PRHRS during some accidents of the Chinese pressurized reactor. The present work has very important realistic significance to the engineering design and assessment of the water cooling PRHRS for Chinese NPPs.