A Study on External Shading Devices for Reducing Cooling Loads and Improving Daylighting in Office Buildings

作者:Kim Minseok; Leigh Seung Bok*; Kim Taeyeon; Cho Sooyoun
来源:Journal of Asian Architecture and Building Engineering, 2015, 14(3): 687-694.
DOI:10.3130/jaabe.14.687

摘要

This study is aimed at analyzing the impact of effective shading design for office buildings. For shade design, the overheated period for the area in which a target building was located was estimated, the building was configured to be shaded during this period, and a different shading design was applied for each direction. Using this shade design, the daylighting performance and the reduction in cooling loads during the overheated period were evaluated. The daylighting performance was evaluated by employing the daylight factor and useful daylight illuminance (UDI). The results showed a 35% reduction in cooling loads due to the shading device. Regarding the daylight factor, more points were included in a proper daylight factor of 2-5%, which was shown to increase the UDI to 500-2,000 lux.

  • 出版日期2015-9