A fast automated screening method for the detection of blood transfusion in sports

作者:Leuenberger Nicolas*; Ansermet Camille; Pottgiesser Torben; Baume Norbert; Robinson Neil; Saugy Martial; Schumacher Yorck Olaf
来源:Drug Testing and Analysis, 2014, 6(11-12): 1141-1143.
DOI:10.1002/dta.1676

摘要

Currently, there is no simple direct screening method for the misuse of blood transfusions in sports. In this study, we investigated whether the measurement of iron in EDTA-plasma can serve as biomarker for such purpose. Our results revealed an increase of the plasma iron level up to 25-fold 6h after blood re-infusion. The variable remained elevated 10-fold one day after the procedure. A specificity of 100% and a sensitivity of 93% were obtained with a proposed threshold at 45 mu g/dL of plasma iron. Therefore, our test could be used as a simple, cost effective biomarker for the screening for blood transfusion misuse in sports.

  • 出版日期2014-12