A new recoil distance technique using low energy coulomb excitation in inverse kinematics

作者:Rother W*; Dewald A; Pascovici G; Fransen C; Friessner G; Hackstein M; Ilie G; Iwasaki H; Jolie J; Melon B; Petkov P; Pfeiffer M; Pissulla Th; Zell K O; Jakobsson U; Julin R; Jones P; Ketelhut S; Nieminen P; Peura P; Rahkila P; Uusitalo J; Scholey C; Harissopulos S; Lagoyannis A; Konstantinopoulos T; Grahn T; Balabanski D
来源:Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment , 2011, 654(1): 196-205.
DOI:10.1016/j.nima.2011.05.075

摘要

We report on the first experiment combining the Recoil Distance Doppler Shift technique and multistep Coulomb excitation in inverse kinematics at beam energies of 3-10 A MeV. The setup involves a standard plunger device equipped with a degrader foil instead of the normally used stopper foil. An array of particle detectors is positioned at forward angles to detect target-like recoil nuclei which are used as a trigger to discriminate against excitations in the degrader foil. The method has been successfully applied to measure lifetimes in (128)Xe and is suited to be a useful tool for experiments with radioactive ion beams.

  • 出版日期2011-10-21