Assessment of temporary cerebral effects induced by focused ultrasound with optical coherence tomography angiography

作者:Tsai Meng Tsan; Zhang Jia Wei; Wei Kuo Chen; Yeh Chih Kuang; Liu Hao Li*
来源:Biomedical Optics Express, 2018, 9(2): 507-517.
DOI:10.1364/BOE.9.000507

摘要

Focused ultrasound (FUS) in combination with microbubbles temporally and locally increases the permeability of the blood-brain barrier (BBB) for facilitating drug delivery. However, the temporary effects of FUS on the brain microstructure and microcirculation need to be addressed. We used label-free optical coherence tomography (OCT) and OCT angiography (OCTA) to investigate the morphological and microcirculation changes in mouse brains due to FUS exposure at different power levels. Additionally, the recovery progress of the induced effects was studied. The results show that FUS exposure causes cerebral vessel dilation and can be identified and quantitatively analyzed via OCT/OCTA. Micro-hemorrhages can be detected when an excessive FUS exposure power is applied, causing the degradation of OCTA signal owing to strong scattering by leaked red blood cells (RBCs) and weaker backscattered intensity from RBCs in vessels. The vessel dilation effect due to FUS exposure was found to abate in several hours. This study demonstrates that the FUS-induced cerebral transiently dilated effects can be in-vivo differentiated and monitored with OCTA, and shows the feasibility of using OCT/OCTA as a novel tool for long-time monitoring of cerebral vascular dynamics during FUS-BBB opening process.