A Novel Automated Assay for the Rapid Identification of Metastatic Breast Carcinoma in Sentinel Lymph Nodes

作者:Feldman Sheldon; Krishnamurthy Savitri*; Gillanders William; Gittleman Mark; Beitsch Peter D; Young Peter R; Streck Christian J; Whitworth Pat W; Levine Edward A; Boolbol Susan; Han Linda K; Hermann Robert; Hoon Dave S B; Giuliano Armando E; Meric Bernstam Funda
来源:Cancer, 2011, 117(12): 2599-2607.
DOI:10.1002/cncr.25822

摘要

BACKGROUND: The authors prospectively evaluated the performance of a proprietary molecular testing platform using one-step nucleic acid amplification (OSNA) for the detection of metastatic carcinoma in sentinel lymph nodes (SLNs) in a large multicenter trial and compared the OSNA results with the results from a detailed postoperative histopathologic evaluation (reference pathology) and from intraoperative imprint cytology (IC). METHODS: In total, 1044 SLN samples from 496 patients at 11 clinical sites were analyzed. Alternate 1-mm sections were subjected to either detailed histopathologic evaluation with hematoxylin and eosin and pancytokeratin immunostaining or the OSNA Breast Cancer System, which was calibrated to detect tumor deposits >0.2 mm by measuring cytokeratin 19 messenger RNA. At 7 sites, IC was performed before permanent section. The OSNA results were classified as negative (<250 copies/mu L), micrometastases (from >= 250 to <5000 copies/mu L), or macrometastases (>= 5000 copies/mu L). RESULTS: The sensitivity and specificity of the OSNA breast cancer system compared with reference pathology were 77.5% (95% confidence interval, 69.7%-84.2%) and 95.8% (95% confidence interval, 94.3%-97.0%), respectively, before discordant case analyses (DCA). Sensitivity and specificity after DCA were 82.7% and 97.7%, and final concordance was 95.8%. Performance for invasive lobular carcinoma demonstrated 88.2% sensitivity (95% confidence interval, 63.6%-98.5%) and 98.5% specificity (95% confidence interval, 92%-100%). The sensitivity of OSNA was significantly better than that of IC (80% vs 63%; P=.0229). CONCLUSIONS: The OSNA breast cancer system proved to be highly accurate for the detection of metastatic breast cancer in axillary SLNs. Sensitivity was comparable to that predicted for conventional postoperative histologic examination at 2-mm intervals and was significantly more sensitive than IC. Automation, semiquantitative results enabling the differentiation of macrometastasis and micrometastasis, and rapid results render the assay suitable for intraoperative and/or permanent evaluation of SLNs. Cancer 2011; 117: 2599-607.

  • 出版日期2011-6-15