A posterior anal sling for fecal incontinence: results of a 152-patient prospective multicenter study

作者:Mellgren Anders; Zutshi Massarat; Lucente Vincent R; Culligan Patrick; Fenner Dee E*
来源:American Journal of Obstetrics and Gynecology, 2016, 214(3): 349.e1-e8.
DOI:10.1016/j.ajog.2015.10.013

摘要

BACKGROUND: The transobturator posterior anal sling (TOPAS) system is a posterior anal sling that is a minimally invasive, self-fixating polypropylene mesh intended to treat fecal incontinence (FI) in women who have failed conservative therapy. OBJECTIVE: We are reporting 1-year outcome in a prospective, multicenter study under investigational device exemption, evaluating this new treatment modality. STUDY DESIGN: A total of 152 women were implanted with the TOPAS system at 14 centers in the United States. FI was assessed pre-operatively and at the 12-month follow up with a 14-day bowel diary, Cleveland Clinic Incontinence Scores, and FI Quality of Life questionnaires. Treatment success was defined as reduction in number of FI episodes of >= 50% compared to baseline. Missing bowel diary data were considered treatment failures. The Wilcoxon signed rank test was used to compare changes observed at 12 months vs baseline. RESULTS: Mean age was 59.6 years old (SD 9.7). The mean duration of FI was 110 mo (range 8-712) months. Mean length of the implant procedure was 33.4 (SD 11.6) minutes. Mean EBL was 12.9 (SD 10.5) mL. Average follow-up was 24.9 months. At 12 months, 69.1% of patients met the criteria for treatment success, and 19% of subjects reported complete continence. FI episodes/wk decreased from a median of 9.0 (range 2-40) at baseline to 2.5 (range 0-40) (P < .001). FI days decreased from a median of 5.0 (range 1.5-7) at baseline to 2.0 (range 0-7) (P < .001) over a 7-day period. FI associated with urgency decreased from a median at baseline of 2.0 (range 0-26) to 0 (range 0-14.5) (P < .001). The mean Cleveland Clinic Incontinence Scores decreased from 13.9 at baseline to 9.6 at 12 months (P < .001). FI Quality of Life scores for all 4 domains improved significantly from baseline to 12 months (P < .001). A total of 66 subjects experienced 104 procedure-and/or device-related adverse events (AEs). Most AEs were short in duration and 97% were managed without therapy or with nonsurgical interventions. No treatment-related deaths, erosions, extrusions, or device revisions were reported. The most common AE categories were pelvic pain (n = 47) and infection (n = 26). Those subjects experiencing pelvic pain had a mean pain score (0-10 scale, 0 = no pain) during the 12-month follow-up of 1.2 (SD 2.4). CONCLUSION: The TOPAS system provides significant improvements in FI symptoms and quality of life with an acceptable AE profile and may therefore be a viable minimally invasive treatment option for FI in women.

  • 出版日期2016-3