A new method to measure mesiodistal angulation and faciolingual inclination of each whole tooth with volumetric cone-beam computed tomography images

作者:Tong Hongsheng*; Enciso Reyes; Van Elslande Dana; Major Paul W; Sameshima Glenn T
来源:American Journal of Orthodontics and Dentofacial Orthopedics, 2012, 142(1): 133-143.
DOI:10.1016/j.ajodo.2011.12.027

摘要

Introduction: The purpose of this study was to develop a methodology to measure the mesiodistal angulation and the faciolingual inclination of each whole tooth (including the root) by using 3-dimensional volumetric images generated from cone-beam computed tomography scans. Methods: A plastic typodont with 28 teeth in ideal occlusion was fixed in position in a dry human skull. Stainless steel balls were fixed to the occlusal centers of the crowns and to the apices or bifurcation or trifurcation centers of the roots. Cone-beam computed tomography images were taken and rendered in Dolphin 3D (Dolphin, Chatsworth, Calif). The University of Southern California root vector analysis program was developed and customized to digitize the crown and root centers that define the long axis of each whole tooth. Special algorithms were used to automatically calculate the mesiodistal angulation and the faciolingual inclination of each whole tooth. Angulation measurements repeated 5 times by using this new method were compared with the true values from the coordinate measuring machine measurements. Next, the root points of 8 selected typodont teeth were modified to generate known angulation and inclination values, and 5-time repeated measurements of these teeth were compared with the known values. Results: Intraclass correlation coefficients for the repeated mesiodistal angulation and faciolingual inclination measurements were close to 1. Comparisons between our 5-time repeated angulation measurements and the coordinate measuring machine's true angulation values showed 5 teeth with statistically significant differences. However, only the maxillary right lateral incisor showed a mean difference that might exceed 2.5 degrees for clinical significance. Comparisons between the 5-repeated measurements of 8 teeth with known mesiodistal angulation and faciolingual inclination values showed no statistically significant differences between the measured and the known values, and no measurement had a 95% confidence interval beyond 1 degrees. Conclusions: We have developed the novel University of Southern California root vector analysis program to accurately measure each whole tooth mesiodistal angulation and faciolingual inclination, in a clinically significant level, directly from the cone-beam computed tomography volumetric images. (Am J Orthod Dentofacial Orthop 2012;142:133-43)

  • 出版日期2012-7