Air Pollution Monitoring and Control System for Subway Stations Using Environmental Sensors

作者:Kim Gyu Sik*; Son Youn Suk; Lee Jai Hyo; Kim In Won; Kim Jo Chun; Oh Joon Tae; Kim Hiesik
来源:Journal of Sensors, 2016, 2016: 1865614.
DOI:10.1155/2016/1865614

摘要

The metropolitan city of Seoul uses more energy than any other area in South Korea due to its high population density. It also has high emissions of air pollutants. Since an individual usually spends most of his/her working hours indoors, the ambient air quality refers to indoor air quality. In particular, PM 10 concentration in the underground areas should be monitored to preserve the health of commuters in the subway system. Seoul Metro and Seoul Metropolitan Rapid Transit Corporation measure several air pollutants regularly. In this study, the accuracy of an instrument for PM measurement using the light scattering method was improved with the help of a linear regression analysis technique to continuously measure the PM 10 concentrations in subway stations. In addition, an air quality monitoring system based on environmental sensors was implemented to display and record the data of PM 10, CO 2, temperature, and humidity. Through experimental studies, we found that ventilation fans could improve air quality and decrease PM 10 concentrations in the tunnels effectively by increasing the air flow rate.

  • 出版日期2016