Design and Control of a 1-DOF MRI-Compatible Pneumatically Actuated Robot With Long Transmission Lines

作者:Yang Bo*; Tan U Xuan; McMillan Alan B; Gullapalli Rao; Desai Jaydev P
来源:IEEE/ASME Transactions on Mechatronics, 2011, 16(6): 1040-1048.
DOI:10.1109/TMECH.2010.2071393

摘要

This paper presents the design and control of an MRI-compatible 1-DOF needle-driver robot and its precise position control using pneumatic actuation with long transmission lines. MRI provides superior image quality compared to other imaging modalities, such as computed tomography or ultrasound, but imposes severe limitations on the material and actuator choice (to prevent image distortion) due to its strong magnetic field. We are primarily interested in developing a pneumatically actuated breast biopsy robot with a large force bandwidth and precise targeting capability during RF ablation (RFA) of breast tumor, and exploring the possibility of using long pneumatic transmission lines from outside the MRI room to the device in the magnet to prevent any image distortion whatsoever. This paper presents a model of the entire pneumatic system. The pneumatic lines are approximated by a first-order system with time delay, since its dynamics are governed by the telegraph equation with varying coefficients and boundary conditions, which cannot be solved precisely. The slow response of long pneumatic lines and valve subsystems make position control challenging. This is further compounded by the presence of nonuniform friction in the device. Sliding-mode control (SMC) was adopted, where friction was treated as an uncertainty term to drive the system onto the sliding surface. Three different controllers were designed, developed, and evaluated to achieve precise position control of the RFA probe. Experimental results revealed that all SMCs gave satisfactory performance with long transmission lines. We also performed several experiments with a 3-DOF fiber-optic force sensor attached to the needle driver to evaluate the performance of the device in the MRI under continuous imaging.

  • 出版日期2011-12