Dry steam cycle application for excess steam utilization: Kamojang geothermal power plant case study

作者:Prananto Lukman Adi*; Juangsa Firman Bagja; Iqbal Riza Mochamad; Aziz Muhammad*; Soelaiman Tubagus Ahmad Fauzi
来源:Renewable Energy, 2018, 117: 157-165.
DOI:10.1016/j.renene.2017.10.029

摘要

This study investigated the utilization of available excess steam by the Kamojang geothermal power plant, which, owing to the vapor-domination of the steam, utilizes a dry steam cycle. A model of the system was validated against actual Kamojang Unit-2 data and found to produce accurate results within a low discrepancy level (<5% error). The modeled performance of the proposed system was obtained through optimization of the non-condensable gases (NCGs) gas removal system (GRS) based on heat balance calculations and assuming content of NCGs in the working fluid based on real operational data. To optimize the model, five GRS configurations were investigated: one-stage steam ejector, two-stage steam ejector, one-stage liquid ring vacuum pump (LRVP), two-stage LRVP, and hybrid system (ejector plus LRVP). To set constraints on the optimization, the allowable condenser pressure was defined based on the cooling water temperature and the maximum temperature difference. Under the best design configuration (a one-stage LRVP), the proposed plant generated a gross electric power of 15.9 MW with a parasitic power consumption of 755.2 kW. The proposed system to convert unused discharge steam into electricity suggests that its installation will result in an increase of the Kamojang geothermal power plant capacity.

  • 出版日期2018-3