摘要

There is a complex interplay between the four conductivity values used in the bidomain equation and the resulting electric potential distribution in cardiac tissue arising from subendocardial ischaemia. Based on the three commonly used experimentally derived conductivity data sets, a non-dimensional formulation of the passive bidomain equation is derived, which gives rise naturally to several dimensionless conductivity ratios. The data sets are then used to define a parameter space of these ratios, which is studied by considering the correlation coefficients between different epicardial potential distributions.
From this study, it is shown that the ratio of the intracellular longitudinal conductivity to the intracellular transverse conductivity is the key parameter in explaining the differences between the epicardial potential distributions observed with these three data sets.

  • 出版日期2011-8