摘要

Pentachlorophenol (PCP), a widely-used aseptic or biocide, is known as an environmental toxicant involved in endocrine disruption even at a trace level. In order to reliably and efficiently quantify environmental trace-quantity PCP, this study developed a novel PCP detection method using the aryl hydrocarbon receptor (AhR) and fluorescence quantitative PCR (qPCR). DNA probe with AhR binding sites was synthesized by PCR before added into AhR-PCP complex. After AhR-PCP-DNA complex was digested with exonuclease, copy number of DNA probe was determined using fluorescence qPCR. To calculate PCP concentration in samples, a standard curve (PCP concentration versus Ct value) was constructed and the detection range was 10(-13) to 10(-9) M. PCP detection limit was 0.0089 ppt for the AhR-PCP-DNA complex assay and 8.8780 ppm for high performance liquid chromatography, demonstrating that the method developed in this study is more sensitive. These results suggest that AhR-PCP-DNA complex method may be successfully applicable in detection and quantification of environmental trace-level PCP.