Deflectometric analysis of high volume injection molds for production of occupational eye wear

作者:Speck Alexis*; Zelzer Benedikt; Speich Marco; Boerret Rainer; Langenbucher Achim; Eppig Timo
来源:Zeitschrift für Medizinische Physik, 2013, 23(4): 314-323.
DOI:10.1016/j.zemedi.2013.08.003

摘要

Purpose: Most of the protective eye wear devices currently on the market are manufactured on simple polycarbonate shields, produced by injection molding techniques. Despite high importance of optical quality, injection molds are rarely inspected for surface quality before or during the manufacturing process. Quality degradation is mainly monitored by optical testing of the molded parts. The purpose of this work was to validate a non-contact deflectometric measurement technique for surface and shape analysis of injection molds to facilitate deterministic surface quality control and to monitor minor conformity of the injection mold with the design data. %26lt;br%26gt;Material and Methods: The system is based on phase-measuring deflectometry with a operating measurement field of 80 x 80 mm(2) (+/-18 degrees slope), a lateral resolution of 60 mu m and a local sensitivity of some nanometers. The calibration was tested with a calibration normal and a reference sphere. The results were crosschecked against a measurement of the same object with a tactile coordinate measuring machine. %26lt;br%26gt;Eight injection molds for production of safety goggles with radii of +58 mm (convex) and -60 mm (concave) were measured in this study. The molds were separated into two groups (cavity I and 2 of the tool with different polishing techniques) and measured to test whether the measurement tool could extract differences. The analysis was performed on difference height between the measured surface and the spherical model. %26lt;br%26gt;Results: The device could derive the surface change due to polishing and discriminate between both polishing techniques, on the basis of the measured data. The concave nozzle sides of the first group (cavity 1) showed good shape conformity. In comparison, the nozzle sides of the second group (cavity 2) showed local deviations from design data up to 14.4 mu m. Local form variations of about 5 mu m occurred in the field of view All convex ejector sides of both groups (cavity I and 2) showed rotational symmetric errors and the molds were measured in general flatter than design data. %26lt;br%26gt;Conclusion: We applied a deflectometric system for measuring and evaluating specular reflective injection molding tools to optimize the production process of occupational eye wear The surface quality could be inline monitored in the production processes for actual spectacle models.

  • 出版日期2013