摘要

In this paper, flow analysis for a non-Newtonian third grade blood in coronary and femoral arteries is simulated numerically. Blood is considered as the third grade non-Newtonian fluid under periodic body acceleration motion and pulsatile pressure gradient. Differential Quadrature Method (DQM) and Crank Nicholson Method (CNM) are used to solve the Partial Differential Equation (PDE) governing equation by which a good agreement between them was observed in the results. The influences of some physical parameters such as amplitude, lead angle and body acceleration frequency on non-dimensional velocity and profiles are considered. For instance, the results show that increasing the amplitude, A(g), and reducing the lead angle of body acceleration, phi, make higher velocity profiles in the center line of both arteries.

  • 出版日期2016-2-1