Detectability of Choledocholithiasis on CT: The Effect of Positive Intraduodenal Enteric Contrast on Portovenous Contrast-enhanced Studies

作者:Ajlan Amr M*; Mesurolle Benoit; Stein Lawrence; Kao Ellen; Artho Giovanni; Al Rujaib Mashael; Reinhold Caroline
来源:Saudi Journal of Gastroenterology, 2015, 21(5): 306-312.
DOI:10.4103/1319-3767.164184

摘要

Background/Aim: To retrospectively assess the accuracy of intravenous (IV) contrast-enhanced multidetector CT (MDCT) in choledocholithiasis detectability, in the presence and absence of positive intraduodenal contrast. Patients and Methods: Over a 3-year period, patients in whom endoscopic retrograde cholangiopancreatography (ERCP) was performed within a week from a portovenous (PV)-enhanced abdominal CT were identified. The final cohort consisted of 48 CT studies in which the entire common bile duct (CBD) length was visualized (19 males, 29 females; mean age, 68 years). We identified two groups according to the absence (n = 31) or presence (n = 17) of positive intraduodenal contrast. CT section thickness ranged from 1.25 to 5 mm. Two radiologists, blinded to clinical information and ERCP results, independently evaluated the CT images. Direct CBD stone visualization was assessed according to previously predefined criteria, correlating with original electronic CT reports and using ERCP findings as the reference standard. A third reader retrospectively reviewed all discordant results. The diagnostic performances of both observers and interobserver agreement were calculated for both groups. Results: 77%-88% sensitivity, 50%-71% specificity, and 71%-74% accuracy were obtained in the group without positive intraduodenal contrast, versus 50%-80% sensitivity, 57%-71% specificity, and 59%-71% accuracy in the group with positive intraduodenal contrast. With the exception of the positive predictive value (PPV), all diagnostic performance parameters decreased in the positive intraduodenal contrast group, mostly affecting the negative predictive value (NPV) (71%-78% vs 50%-67%). Conclusion: PV-enhanced MDCT has moderate diagnostic performance in choledocholithiasis detection. A trend of decreasing accuracy was noted in the presence of positive intraduodenal contrast.

  • 出版日期2015-10
  • 单位McGill