A novel flow battery: A lead acid battery based on an electrolyte with soluble lead(II). Part IX: Electrode and electrolyte conditioning with hydrogen peroxide

作者:Collins John; Li Xiaohong*; Pletcher Derek; Tangirala Ravichandra; Stratton Campbell Duncan; Walsh Frank C; Zhang Caiping
来源:Journal of Power Sources, 2010, 195(9): 2975-2978.
DOI:10.1016/j.jpowsour.2009.10.109

摘要

Extended cycling of a soluble lead acid battery can lead to problems due to an imbalance in the coulombic efficiency leading to deposits of Pb and PbO2 on the electrodes. Periodic addition of hydrogen peroxide to the electrolyte of the soluble lead acid flow battery largely overcomes several operational problems seen during extended cycling, using a 10cm x 10cm parallel plate flow cell. It is shown that this treatment greatly extends the number of cycles that can be achieved with a reasonable energy-, voltage-, and charge efficiency of 54-66%, 71%, and 77-91%.

  • 出版日期2010-5-1