ASSESSMENT OF QUADRICEPS MUSCLE INACTIVATION WITH A NEW ELECTRICAL STIMULATION PARADIGM

作者:Wellauer Vanessa; Morf Claudia; Minetto Marco A; Place Nicolas; Maffiuletti Nicola A*
来源:Muscle & Nerve, 2015, 51(1): 117-124.
DOI:10.1002/mus.24266

摘要

Introduction: In this study we evaluated the validity of garment-based quadriceps stimulation (GQS) for assessment of muscle inactivation in comparison with femoral nerve stimulation (FNS). Methods: Inactivation estimates (superimposed doublet torque), self-reported discomfort, and twitch and doublet contractile properties were compared between GQS and FNS in 15 healthy subjects. Results: Superimposed doublet torque was significantly lower for GQS than for FNS at 20% and 40% maximum voluntary contraction (MVC) (P < 0.01), but not at 60%, 80%, and 100% MVC. Discomfort scores were systematically lower for GQS than for FNS (P < 0.05). Resting twitch and doublet peak torque were lower for GQS, and time to peak torque was shorter for GQS than for FNS (P < 0.01). Conclusions: GQS can be used with confidence for straightforward evaluation of quadriceps muscle inactivation, whereas its validity for assessment of contractile properties remains to be determined.

  • 出版日期2015-1

全文