Application of multi-slot sampling method for gas-liquid two-phase flow rate measurement

作者:Liang, Fachun*; Sun, Yuan; Fang, Zhaojun; Sun, Shitao
来源:Experimental Thermal and Fluid Science, 2016, 79: 213-221.
DOI:10.1016/j.expthermflusci.2016.07.014

摘要

A novel approach to measure the individual mass flow rates of gas-liquid two-phase flow was proposed. Gas-liquid two-phase flow was divided into eighteen equal parts by a specially designed sampler and three parts were applied as sample fluid. The total gas and liquid flow rates are determined according to the flow rates of sampled fluid and the extraction ratio. The correlation of extraction ratio is deduced from the relation of resistance between the main loop and the division loop. Experiments were carried out in an air-water two-phase flow loop and the gas quality ranged from 0.008 to 0.66. The observed flow pattern included stratified smooth, stratified wavy, annular and slug flows. It was found that the gas and liquid extraction ratios are very close to the theoretical value (0.167) and independent of inlet flow pattern, gas and liquid velocities. The error of gas and liquid mass flow rates measurements was less than +/- 5.0%.