摘要

Objectives: To determine the preanalytical quality of serum and plasma by monitoring the time-dependent ex vivo decay of a synthetic reporter peptide (RP) with liquid chromatography/mass spectrometry (LC/MS). %26lt;br%26gt;Methods: Serum and plasma specimens were spiked with the RP and proteolytic fragments were monitored with LC/MS at different preanalytical time points ranging from 2 to 24 hours after blood withdrawal. %26lt;br%26gt;Results: The concentration of fragments changed in a time-dependent manner, and respective peptide profiles were used to classify specimens according to their preanalytical time span. Classification accuracy was high, with values always above 0.89 for areas under receiver operating characteristic curves. %26lt;br%26gt;Conclusions: This %26quot;proteomics degradation clock%26quot; can be used to estimate the preanalytical quality of serum and plasma and might have impact on quality control procedures of biobanking repositories.

  • 出版日期2013-9