Diffuse optical characterization of an exercising patient group with peripheral artery disease

作者:Mesquita Rickson C*; Putt Mary; Chandra Malavika; Yu Guoqiang; Xing Xiaoman; Han Sung Wan; Lech Gwen; Shang Yu; Durduran Turgut; Zhou Chao; Yodh Arjun G; Mohler Emile R III
来源:Journal of Biomedical Optics, 2013, 18(5): 057007.
DOI:10.1117/1.JBO.18.5.057007

摘要

Peripheral artery disease (PAD) is a common condition with high morbidity. While measurement of tissue oxygen saturation (StO2) has been demonstrated, this is the first study to assess both StO2 and relative blood flow (rBF) in the extremities of PAD patients. Diffuse optics is employed to measure hemodynamic response to treadmill and pedal exercises in 31 healthy controls and 26 patients. For StO2, mild and moderate/severe PAD groups show pronounced differences compared with controls. Pre-exercise mean StO2 is lower in PAD groups by 9.3% to 10.6% compared with means of 63.5% to 66.2% in controls. For pedal, relative rate of return of StO2 to baseline is more rapid in controls (p %26lt; 0.05). Patterns of rBF also differ among groups. After both exercises, rBF tend to occur at depressed levels among severe PAD patients compared with healthy (p %26lt; 0.05); post-treadmill, rBF tend to occur at elevated levels among healthy compared with severe PAD patients (p %26lt; 0.05). Additionally, relative rate of return to baseline StO2 is more rapid among subjects with reduced levels of depression in rBF (p = 0.041), even after adjustment for ankle brachial index. This suggests a physiologic connection between rBF and oxygenation that can be measured using diffuse optics, and potentially employed as an evaluative tool in further studies.

  • 出版日期2013-5