Disposable sensor for quantitative determination of hydrazine in water and biological sample

作者:Abbaspour Abdolkarim*; Mirahmadi Ehsan; Khajehzadeh Abdolreza
来源:Analytical Methods, 2010, 2(4): 349-353.
DOI:10.1039/b9ay00291j

摘要

A method for determination of hydrazine is described. The sensor was constructed by immobilizing a reagent on TLC (Thin Layer Chromatography) paper. This procedure is based on chromogenic reaction of hydrazine with p-(dimethylamino)benzaldehyde (reagent) and formation of red colour product followed by scanner-based detection. Changes in RGB values of colour spots on TLC strips create a pattern. The obtained pattern was analyzed by MATLAB software. The proposed sensor is linear in concentration range of 10-300 mu g mL(-1) of hydrazine and has practical detection limit of 0.1 mu g mL(-1). Parameters such as pH and concentration of p-(dimethylamino)benzaldehyde were optimized. The proposed sensor was successfully applied for the determination of hydrazine in bovine scrum and tap water.

  • 出版日期2010-4