Introduction: The purpose of this study was to determine whether there is a difference in the in vivo diagnostic accuracy of digital radiography (DR) and cone-beam computed tomography (CBCT) imaging in the detection of vertical root fracture (VRF). The presence/absence of VRF was confirmed by visual inspection of the extracted root surface and was the reference standard against which both imaging modalities were compared. Methods: Twenty-one unsalvageable teeth from 20 patients that had been radiographed and scanned with CBCT imaging were included in the study. The teeth were atraumatically extracted and visually inspected under a microscope to confirm the presence/absence of fracture. The widest point of each fracture was recorded using an optical coherence tomography scanner in order to quantify the size of fractures. Images were viewed under standardized conditions by 13 examiners and repeated 2 weeks later to assess their consistency. Results: DR and CBCT imaging showed similarly poor sensitivity of 0.16 and 0.27, respectively. Both imaging modalities had similarly high specificity of 0.92 and 0.83, respectively. There was no statistical difference between the diagnostic accuracy of either imaging modality. Fracture width did not affect the detection rate of either imaging modality. Receiver operating characteristic analysis revealed mean A(z) values of 0.535 and 0.552 for DR and CBCT imaging, respectively. Conclusions: Both DR and CBCT imaging have significant limitations when detecting vertical root fractures.