摘要

This paper presents the new switching converter model used for analyzing the generation mechanism of ringing ground leakage (GL) current, generated during the transient, at switch on/off of any switching converter. By applying the Norton model, the proposed new model of switching converter can be formulated. The ringing GL current is evaluated at the switching on/off of the unbalanced (half-bridge converter) and the balanced converter (full-bridge converter) for bidirectional D.C. motor drive used as an example. It is concluded that the measured and simulated results of the generated GL current agree well with the numerical analysis results, analyzed by the proposed new model of switching converter, in terms of the minimum or maximum peak currents and the ringing frequency.