Comparison of ultrasonic degradation rates constants of methylene blue at 22.8 kHz, 127 kHz, and 490 kHz

作者:Kobayashi Daisuke*; Honma Chiemi; Suzuki Atsushi; Takahashi Tomoki; Matsumoto Hideyuki; Kuroda Chiaki; Otake Katsuto; Shono Atsushi
来源:Ultrasonics Sonochemistry, 2012, 19(4): 745-749.
DOI:10.1016/j.ultsonch.2012.01.004

摘要

Techniques such as solvent extraction, incineration, chemical dehalogenation, and biodegradation have been investigated for the degradation of hazardous organic compounds. We found ultrasound to be an attractive technology for the degradation of hazardous organic compounds in water. However, the effects of ultrasonic frequency on degradation rate constants were not investigated quantitatively. In this study, the degradation process of a model for hazardous organic compound methylene blue was investigated using ultrasonic irradiation. The study focused on the effects of ultrasonic frequency and ultrasonic power on the degradation rate constant. The apparent degradation rate constants were estimated based on time dependence of methylene blue concentration assuming pseudo-first-order kinetics for the decomposition. A linear relationship between the apparent degradation rate constant and ultrasonic power was identified. In addition, the apparent degradation rate constants at frequencies of 127 and 490 kHz were much larger than those at 22.8 kHz. A relationship between the apparent degradation rate constant and the sonochemical efficiency value (SE value) was also found. Based on these results, a simple model for estimating the apparent degradation rate constant of methylene blue based on the ultrasonic power and the SE value is proposed in this study.

  • 出版日期2012-7