Advances in the metabolic profiling of acidic compounds in children's urines achieved by comprehensive two-dimensional gas chromatography

作者:Vasquez N Perez; de Bellaistre Bonose M Crosnier*; Leveque N; Thioulouse E; Doummar D; de Villemeur T Billette; Rodriguez D; Couderc R; Robin S; Courderot Masuyer C; Moussa F
来源:Journal of Chromatography B-Analytical Technologies in the Biomedical and Life Sciences, 2015, 1002: 130-138.
DOI:10.1016/j.jchromb.2015.08.006

摘要

The main objective of this work was to evaluate a comprehensive two-dimensional gas chromatographic (GCxGC) coupled to quadrupole mass spectrometry (qMS) method in the field of biomarker candidates' discovery. To this purpose we developed a GCxGC-qMS method suitable for the separation of organic acids and other classes of compounds with silylable polar hydrogen such as sugars, amino-acids, and vitamins. As compared to those obtained by a widely used 1D-GC method, the urinary chromatographic profiles performed by the proposed 2D-GC method exhibit higher resolution and sensitivity, leading to the detection of up to 92 additional compounds in some urine samples including some well-known biomarkers. In order to validate the proposed method we focused on three metabolites of interest with various functional groups and polarities including CH3-malonic acid (MMA: biomarker of methylmalonic acidemia), 3-hydroxy-3-methyl-glutaric acid (3-OHMGA: biomarker of 3-hydroxy-3-methylglutaric acidemia), and phenylpiruvic acid (PhPA: marker of phenylketonuria). While these three metabolites can be considered as representative of organic acids classically determined by 1D-GC, they cannot be representative of new detected metabolites. Thus, we also focused on quinolic acid (QUIN), taken as an example of biomarker not detected at basal levels with the classical 1D GC-qMS method. In order to obtain sufficient recoveries for all tested compounds, we developed a sample preparation protocol including a step of urea removal followed by two extraction steps using two solvents of different polarity and selectivity. Recoveries with the proposed method reached more than 80% for all targeted compounds and the linearity was satisfactory up to 50 mu mol/L. The CVs of the within-run and within-laboratory precisions were less than 8% for all tested compounds. The limits of quantification (LOQs) were 0.6 mu mol/L for MMA, 0.4 mu mol/L for 3-OHMGA, 0.7 mu mol/L for PhPA, and 1 mu mol/L for QUIN. The LOQs of these metabolites obtained by a classical GC-MS method under the same chromatographic conditions were 5 mu mol/L for MMA, 4 mu mol/L for 3-OHMGA, 6 mu mol/L for PhPA while QUIN was below the limit of detection. As compared to 1D-GC, these results highlight the enhanced detectability of urine metabolites by the 2D-GC technique. Our results also show that for each new detected compound it is necessary to develop and validate an appropriate sample preparation procedure.

  • 出版日期2015-10-1