To assess the usefulness of multiple arterial phase (AP) of gadoxetic acid-enhanced MRI using view-sharing of two different vendors to reduce transient severe motion (TSM) artifact in the AP.
This retrospective study included 298 patients (mean age 63 years) who underwent gadoxetic acid MRI with multiple AP from two different vendors; either triple (subcohort A, n=174) or quadruple (subcohort B, n=124) AP. 202 patients (143 vs. 59) underwent follow-up MRI with single AP. To compare multiple AP with single AP and between subcohorts, mean artifact score rated by two observers and frequency of significant artifacts were evaluated. Frequency of acquisition of late AP was also assessed.
There was no difference in mean artifact score (p=0.086) or frequency of significant artifacts (p=0.219) between multiple AP and single AP. For the mean best score with multiple AP, subcohort B was better than subcohort A (p < 0.001). Late AP was achieved more often with multiple AP (74.8 %, 98.3 %) than with single AP (64.3 %, 64.4 %).
Multiple AP using different view-sharing failed to show differences in TSM artifacts in AP compared to single AP. Frequency of acquisition of late AP was higher with multiple AP. Mean best artifact score of multiple AP is different depending on view-sharing technique.
TSM artifacts were not significantly different between multiple AP and single AP.
The frequency of acquiring late AP was higher with multiple AP.
For multiple APs, TSM artifacts are different according to view-sharing technique.

  • 出版日期2018-8