Feasibility of optical coherence tomography angiography to assess changes in retinal microcirculation in ovine haemorrhagic shock

作者:Alnawaiseh Maged; Ertmer Christian; Seidel Laura; Arnemann Philip Helge; Lahme Larissa; Kampmeier Tim Gerald; Rehberg Sebastian Willy; Heiduschka Peter; Eter Nicole; Hessler Michael*
来源:Critical Care, 2018, 22(1): 138.
DOI:10.1186/s13054-018-2056-3

摘要

Background: This study aimed to investigate the feasibility of optical coherence tomography angiography (OCT-A) for quantitative analysis of flow density to assess changes in retinal perfusion in an experimental model of haemorrhagic shock.
Methods: Haemorrhagic shock was induced in five healthy, anaesthetized sheep by stepwise blood withdrawal of 3 x 10 ml.kg(-1) body weight. OCT-A imaging of retinal perfusion was performed using an OCT device. Incident dark-field illumination microscopy videos were obtained for the evaluation of conjunctival microcirculation. Haemodynamic variables and flow density data in the OCT angiogram were analysed before and during progressive haemorrhage resulting in haemorrhagic shock as well as after fluid resuscitation with 10 ml.kg(-1) body weight of balanced hydroxyethyl starch solution (6% HES 130/0.4). Videos of the conjunctival microcirculation were recorded at baseline, in haemorrhagic shock, and after resuscitation. Data are presented as median with interquartile range. Comparisons between time points were made using Friedman's test and the degree of correlation between two variables was expressed as Spearman's rank correlation coefficient.
Results: Mean arterial pressure and cardiac index (CI) decreased and lactate concentration increased after induction of shock, and haemodynamics recovered after resuscitation. The flow density in the superficial retinal OCT angiogram decreased significantly after shock induction (baseline 44.7% (40.3; 50.5) vs haemorrhagic shock 34.5% (32.8; 40.4); P = 0.027) and recovered after fluid resuscitation (46.9% (41.7; 50.7) vs haemorrhagic shock; P = 0.027). The proportion of perfused vessels of the conjunctival microcirculation showed similar changes. The flow density measured using OCT-A correlated with the conjunctival microcirculation (perfused vessel density: Spearman's rank correlation coefficient rho = 0.750, P = 0.001) and haemodynamic parameters (CI:. = 0.693, P < 0.001).
Conclusions: Retinal flow density, measured using OCT-A, significantly decreased in shock and recovered after fluid therapy in an experimental model of haemorrhagic shock. OCT-A is feasible to assess changes in retinal perfusion in haemorrhagic shock and fluid resuscitation.

  • 出版日期2018-5-29