Experimental results on dryout of seven refrigerants (R134a, R1234yf, R152a, R22, R245fa, R290 and R600a) in small, single vertical tubes under upward flow conditions are reported in this study. The experiments were conducted under a wide range of operating conditions in stainless steel tubes (0.64-1.70 mm and 213-245 mm heated length). The effects of operating parameters like mass flux, vapor quality, saturation pressure and channel size are discussed in detail. In general, dryout heat flux increased with increasing mass flux, and with increasing tube diameter. No effect of varying saturation temperature was observed. The experimental findings were compared with well-known macro and micro-scale correlations from the literature and it was found that Wu's correlation (in modified form) quite satisfactorily predicted the whole database. A new correlation for prediction of heat flux at dryout conditions is also proposed.