摘要

Pretension deviation may cause stiffness degradation and overstress that can compromise the safety of tensile structures, which can be diagnosed by modal identification. This article presents modal tests on a 1:10 scaled model of a herringbone-ribbed cable dome structure. An optimal sensor placement scheme is proposed to observe the geometric stiffness change induced by pretension deviation. Based on the tests, different output-only modal identification techniques were implemented. A substructure strategy was adopted to overcome the limited measurement quantity and provide localized diagnoses. The experimental results show that operational modal analysis methods based on output-only data can effectively identify major modes of massive structures. The sensitivity of modal characteristics to pretension deviation is also evaluated via experimental comparisons, and modifications are implemented in an analytical finite element model to approximate the test model. The identified modal information can help locate stiffness degradation and thereby pretension loss in tensile structures. A modified modal strain energy method is proposed to detect pretension loss from decentralized testing and is verified by the test results.